Mid Blower Door Test

We offer independent, impartial energy assessments and clear, practical advice based on local expertise to help your home perform better and use energy more efficiently.

Mid Blower Door Test
Mid Blower Door Testing Service

BC Energy Step Code – Mid Blower Door Testing Service

A Mid-Construction Blower Door Test (MCBDT) checks how airtight a building is once the framing, windows and doors, rough-ins, and main air barrier are complete—but before interior insulation, if applicable, and drywall are installed.

For a General Contractor, a mid construction blower door test is your cheapest insurance policy against failing your final BC Energy Step Code As Built test for your Occupancy Permit.

— BC Step Code Builder

Why A Mid Blower Door Test Is Important

No confusing jargon or surprises. Here’s what to expect when you book an EnerGuide evaluation with Airtight Energy Advisors, what you’ll see, and what you’ll receive at the end.

  • Catch leaks while walls are open: Finding and sealing air leaks at framing/air-barrier stage takes hours with caulking, tape, or foam. Finding them at occupancy requires tearing into finished drywall or paying for expensive aerosol sealing.
  • Step 3+ requires tight envelopes: With Step 3 as the provincial minimum ($\le 2.5\text{ ACH}{50}$) and many municipalities pushing Step 4 ($\le 1.5\text{ ACH}{50}$) or Step 5 ($\le 1.0\text{ ACH}_{50}$), hitting targets by accident is nearly impossible.
  • Municipal mandates: While technically diagnostic under the BC Building Code, several municipalities (e.g., Surrey, Abbotsford, Regional District of Nanaimo) require a mid-construction report before passing your insulation/vapour barrier inspection.

The Energy Modelling and Reports bring clarity and priority for BC Energy Step Code compliance.

Louise Airtight Energy Advisor Step Code Builders
Experts in Mid Blower Door Testing
The Start of a Home energy Evaluation
The Start of a Home energy Evaluation

The EnerGuide Evaluation Nanaimo On-site visit

What to Expect: Our Government certified and licensed Advisor collects energy-related data by measuring building assemblies, taking photos of mechanical systems and attic/crawl spaces for calculating heat loss & heat gain.

  • Floor Plans with to scale dimensions for perimeter walls, conditioned area, & volume;
  • Insulation R-Values for Ceiling, Walls, and Foundation;
  • Window Panes, Frames, Fixed/Opens, Skylights, Exterior Doors;
  • Front Wall/Door Sun Orientation;
  • Air Leakage measured by a Blower Door;
  • Weather data and more….

How To Prepare for A Mid Blower Door Test

Complete these items before your Registered Energy Advisor (REA) arrives so the fan test accurately measures your air barrier rather than unsealed rough-in openings.

  1. Confirm primary air barrier is 100% continuous: Verify all sheathing seams, poly laps (if interior air barrier), and transition membranes are taped or caulked.
  2. Seal bottom plates and rim joists: Check sill gaskets, acoustic sealant beads, and rim board connections to subfloor and top plates.
  3. Seal attic hatch and cantilever/garage transitions: Install temporary poly/tape over rough attic hatches and verify air barrier continuity over garage ceilings.
  4. Seal exterior electrical boxes and penetrations: Boot or foam all exterior wall outlets, hose bibs, gas lines, and exterior lighting boxes.
  5. Verify window and door rough openings are air-sealed: Check interior perimeter low-expansion foam or air-barrier tape around all frames.
  6. Close and latch all exterior windows and doors: Ensure weatherstripping is installed on exterior doors and multipoint locks are engaged.
  7. Temporarily seal all HVAC and exhaust ducts: Tape poly over HRV/ERV intakes and exhausts, range hood ducts, bath fans, and dryer vents.
  8. Cap or tape open plumbing vents and drains: Fill installed P-traps with water and tape over any open floor drains, rough-in stubs, or sump pits.
  9. Seal fireplace flues and combustion air intakes: Close dampers and temporarily tape over direct-vent or makeup air openings.
  10. Open all interior doors and clear main entry: Prop open all interior doors (including closets and mechanical rooms) so pressure equalizes across the entire zone.
  11. Stage air-sealing kit and assign a crew member: Have sheathing tape, acoustic sealant, gun foam, and a ladder on-site during the test for instant fixes.

Continuous exterior insulation can improve effective wall performance and reduce thermal bridging. It must also be coordinated with rain control, drying potential, cladding attachments and window detailing. Evaluate the full wall assembly in the context of the energy model.

Preparing for a Mid Blower Door Test
Preparing for a Mid Blower Door Test
Step Code Pre Checklist Nanaimo
Airtight’s Experienced Mid Blower Door Test Team

Canadian homes frequently lose up to 30% of conditioned air through unseen building envelope gaps (around rim joists, attic hatches, pot lights, and windows), leading to cold drafts, uneven room temperatures, high utility bills, and moisture risks.

How A Mid Blower Test Works On Site

  1. Timing: Schedule your Registered Energy Advisor (REA) once the continuous air barrier, exterior windows/doors, and mechanical/electrical penetrations are sealed, prior to boarding.(Note: If using poly as your primary air barrier, insulation must go in before poly is taped and tested).
  2. The Test: The REA mounts a calibrated fan into an exterior doorway, depressurizes the home to 50 Pascals (simulating a ~30 km/h wind on all sides), and calculates Air Changes per Hour ($\text{ACH}_{50}$).
  3. Diagnostics (The Real Value): While the house is under negative pressure, you and the REA walk the site with a smoke pencil or thermal camera to pinpoint drafts at rim joists, bottom plates, window rough openings, and service penetrations.

The Mid Blower Door Finds air-leaks

A calibrated blower door is fitted to an exterior doorway and the fan blows the home’s air outside, depressurizes the house, the negative pressure creates a strong suction force that helps discover significant holes and cracks in the envelope. The result is a precise number in Air Changes/Hour (ACH@50Pa) that becomes part of your energy model and Rating.

There are two levels of EnerGuide Evaluations. Standard is used for Federal Grant programs. Basic is used when the modeling is limited to modelling a F280 Heat Loss Calculation that uses CGMP comparable home age data points.

ServiceBASICSTANDARD
Full Audit Checkupyesyes
Hot2000 Modellingyesyes
Blower Door testAge Comparable RangeSite Measurement
Locate Air Leaksnoyes
Reno Upgrade Reportnoyes

Combustion Exhaust safety checks follow — confirming that combustion appliances vent properly and that the home isn’t at risk of back-drafting or carbon monoxide.

The Nanaimo Energy Advisor typically invites interested homeowners to walk through the house during the blower door test to physically feel the locations where drafts enter. You can read more about our Blower Door Testing Service page.

F280-12 Heat Loss/Gain Calculation
Blower Door Air-Leakage Test

Does Airtight Service Nanaimo? Yes!

Airtight Energy Advisors is Nanaimo licensed and BC Registered to provide EnerGuide Evaluations, Energy Step Code, and F280 Heat Loss Calculations up and down the Island with limited far-North coverage. Our home Regions are:

  • Regional District Nanaimo energy advisor from Deep Bay to Cedar
  • Greater Victoria Region from Langford, and Sidney to Sooke

Mid Blower Door Test Services

Nanaimo Energy Advisor Services

Home Builders in Nanaimo are supported in the Energy Step Code from Pre-Permit Design, Mid-Blower air-leakage test, and the final As-Built rating.

Nanaimo Homeowners can order a F280-12 Heat Loss/Gain Calculation report produced to right-size adding a Heat Pump or replacing a furnace. The F280 report is required by BC Hydro and Fortis, plus the BC Energy Step Code 9.33.5

We offer independent, impartial energy assessments and clear, practical advice based on local expertise to help your Nanaimo home perform better and use energy more efficiently.

Book the Best Mid Blower Door Test

This whole home F280 is required for the $4,000 Home Reno Heat Pump Rebate from BC Hydro and Fortis. The net price below is strictly for homes in the Regional District of Nanaimo and includes a $300 discount (After Rebate), off the $499 stand-alone price. Stack the National $10,000 and BC $4,000 Rebates.

If you live outside the RDN and your city does not offer a rebate, like Qualicum, Parksville and Lantzville, your price is $499 at the time of writing.

Prepare for Mid Blower Door Test

$ 0 .

* 30-min discussion for a home in the Regional District Nanaimo.

Your Name
Address

Select one

Adults with Net Incomes

After Tax Combined Incomes

Current Property Tax Value

Refer Local HVAC Contractors

We will email 3 HVAC contacts to bid

Licensed Mid Blower Door Tester

Registered Energy Advisor Licenses

Natural Resources Canada logo

The Federal Ministry in charge of Home Energy Efficiency initiatives

EnerGuide Rating System logo black

Comprehensive National home energy rating procedures

BC Housing logo

Home Energy Modelling software used by Energy Advisors for EnerGuide Ratings.

HVAC Designers of Canada

Certification of CSA F280-12 Heat Loss/Gain Calculation software

Best Mid Blower Door Testing

Certified Energy Advisor Memberships

Natural Resources Canada logo

Canadian Home Builders Association Member

EnerGuide Rating System logo black

Home Performance Contractor Network Member Airtight Energy

BC Housing logo

Thermal Environmental Comfort Association Member

HVAC Designers of Canada

Certification of CSA F280-12 Heat Loss/Gain Calculation software

What Is a Mid Blower Door Test?

Energy advisors are independent consultants who help Homeowners and Builders make their buildings more efficient and get rebates. They’re registered through a BC Service Organization and licensed by Natural Resources Canada to deliver the EnerGuide Rating System.

Why Test the Airtightness at Mid Construction?

Energy modellers do similar work, but they aren’t affiliated with a Service Organization or the EnerGuide Rating System. They may use other energy simulation or HVAC design software that meets the BC Energy Step Code’s requirements. Airtight has both Energy Advisor and Energy Modeller complimentary roles.

what air Sealing Strategies Should I Use?

Airtight Energy Advisors can work across BC as a Primary Advisor by sub-contracting with a Secondary Advisor to conduct the local Blower test for our file.

Do I need a Mid Blower Test for a Inspection?

The short answer is No. However in order to stack the BC Heat Pump $4,000 Rebate you need Airtight to complete a F280 Heat Loss/Gain Calculation and Hydro’s Heat Pump Size Summary form to qualify.

What is The Step Code Blower Door Requirements?

Part 9 governs smaller, simpler residential and light commercial structures up to 3 storeys and 600 m² like your home. The BC Building Code has definitions and rules to define Part 9 vs. Part 3 larger, complex buildings.

How much does a Mid Blower Door cost?

Fees start at $499 for a 1100 sq.ft. rectangular home near the Advisor. Homes with longer travel-time, complex shapes, or more than 2900 sq.ft. pay a little more.